Z2AA--36C249-23-AP-0268 - Project 621-19-110 - Correct Exterior Deficiencies Building 53
Looking for contract opportunity help?
Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses.
Find your local PTAC
(opens in new window)
for free government expertise related to contract opportunities.
General Information View Changes
-
Contract Opportunity Type: Solicitation (Updated)
-
All Dates/Times are: (UTC-06:00) CENTRAL STANDARD TIME, CHICAGO, USA
-
Updated Published Date: Jan 24, 2023 03:48 pm CST
-
Original Published Date: Dec 29, 2022 06:15 pm CST
-
Updated Date Offers Due: Feb 08, 2023 01:00 pm CST
-
Original Date Offers Due: Jan 18, 2023 10:00 am CST
-
Inactive Policy: Manual
-
Updated Inactive Date: Mar 10, 2023
-
Original Inactive Date:
Apr 27, 2023
-
Initiative:
Classification
-
Original Set Aside:
-
-
Product Service Code: Z2AA - REPAIR OR ALTERATION OF OFFICE BUILDINGS
-
NAICS Code:
-
236220 - Commercial and Institutional Building Construction
-
Place of Performance:
Description View Changes
Will there be any Asbestos Abatement required as per specs?
I am attaching specifications on the removal of asbestos that is only present in the Glazing of the windows. Only that area will be remedied so far, finding any suspicious areas is GC's responsibility to notify the VA.
Will temporary fencing be required as per specs?
No, Only on the perimeter of the retaining wall excavation.
Can the Contractors' superintendent also carry the duties of the SSHO as laid out in the specs?
Yes, as long as the superintendent has OSHA 30 certification and First aid credentials.
Will a Certified Safety Professional be required on sight?
No, as long as the superintendent has OSHA 30 certification and First aid credentials.
Part A-General Information calls for the replacement of floor tiles and leveling of floors, will the government supply specs sheet section and quantities/areas receiving it?
Yes, See attached specifications, please provide 2,340 sq. ft of black vinyl tile for high traffic, see attached specifications.
Can the Government supply a finish schedule for flooring/ceiling tiles?
Yes, please provide 2,340 sq. ft of black vinyl tile for high traffic, see attached specifications.
Will government employees be responsible for moving any/all workstations for tile installation.
The postmaster will be responsible for moving all the materials and equipment from the area to be worked, it must be coordinated with him so that the material is relocated with at least 48 hours' notice.
Glazing companies, we have reached out to say it will be impossible to alter the existing widows, Will the government except for new windows ILO alterations to existing. If so, can a spec be provided.
No, proceed to reglaze the existing windows and remediate the asbestos in the glazing, and replace the damaged panels.
Is there a limit to the number of widows that may be removed from the building at a time?
No, But you must provide the necessary security to the building after the removal of the windows.
Part A-General Information calls for reconstruction of retaining wall can the government supply drawings, and/or clarification as to what would be expected.
Please see section 03 30 53 for cast in place concrete add attached, and the attached drawing for the retaining wall. The length of the repair will only be the area that is currently affected, about 25 feet long, and as indicated in the field visit, the drainage that passes through the wall must be repaired. Must repair handrails on the top of the wall in its entirety, it must be plumb and painted, Take into consideration that they should asphalt the area after the repairs and repaint all the lines of the parking lines in that area. Please include the repair of the two bollards in the reception area, continuous with the wall, as well as the gutter at that entrance, which is about 12 feet.
As stated in the on-site discussion, please verify the absence of lead paint on the exterior exposed rafter tails.
It is presumed that the rafter tails contain lead paint, so it is necessary to proceed with abetment, see attached specifications.
Per site discussion, please verify that any broken or missing windowpanes will be replaced with new glass of the same thickness as existing conditions and reglazed with linseed oil-based putty as historically correct.
Yes, they will be replaced following the historical parameters
Confirm that (2) additional double hung window units will be constructed to match the existing windows and installed in the west lower openings that are currently boarded over.
Yes, you should provide the two additional windows following the same parameters as the existing windows.
Confirm that the air conditioner located in the lower east window unit will be removed and a new upper sash will be constructed to match the existing windows.
All window-type air conditioners will be removed from the building and in the event of sale will be restored.
Confirm that when re-installed, the repaired windows will be non-operable and weather-sealed.
It is confirmed that when the windows are reinstalled, they will be non-operable and weather-sealed
Confirm the absence of asbestos in the existing tile flooring of the area.
According to the most recent sample, there is no presence of asbestos on the floors in the area where the work will be carried out, but it is the responsibility of the General Contractor to notify the VA of finding suspicious material.
Confirmation that only the retaining wall area will need to be fenced in during that repair.
The only area that will be fenced off will be the area of the retaining wall excavation that will be repaired.