Brand Name DynaPro Nanostar II, MALS Adapter, Software, and Installation

Agency: HEALTH AND HUMAN SERVICES, DEPARTMENT OF
State: Maryland
Type of Government: Federal
Category:
  • 66 - Instruments and Laboratory Equipment
Posted: Apr 19, 2024
Due: Apr 29, 2024
Solicitation No: NOI-NIAID-24-2217058
Publication URL: To access bid details, please log in.
Follow
Brand Name DynaPro Nanostar II, MALS Adapter, Software, and Installation
Active
Contract Opportunity
Notice ID
NOI-NIAID-24-2217058
Related Notice
Department/Ind. Agency
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-tier
NATIONAL INSTITUTES OF HEALTH
Office
NATIONAL INSTITUTES OF HEALTH NIAID
General Information
  • Contract Opportunity Type: Special Notice (Original)
  • All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
  • Original Published Date: Apr 19, 2024 09:52 am EDT
  • Original Response Date: Apr 29, 2024 10:00 am EDT
  • Inactive Policy: 15 days after response date
  • Original Inactive Date: May 14, 2024
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6640 - LABORATORY EQUIPMENT AND SUPPLIES
  • NAICS Code:
    • 334516 - Analytical Laboratory Instrument Manufacturing
  • Place of Performance:
    Gaithersburg , MD 20878
    USA
Description

NOI-NIAID-24-2217058



NAICS – 334516



This is a Notice of Intent, NOT a request for proposal. The National Institute of Allergy and Infectious Diseases (NIAID) of the National Institutes of Health (NIH) intends to negotiate on an other than full and open competition basis with Wyatt Technology for the following:





DynaPro NanoStar II with MALS




  • Simultaneous DLS and SLS- The instrument must provide dynamic light scattering (DLS) and static light scattering (SLS) measurements simultaneously and independently in order to assess and distinguish changes in molecular conformation from aggregation, and to measure particle concentration. The NanoStar accomplishes this by design with parallel DLS and SLS detectors.

  • SLS Calibration- The instrument must be calibrated for SLS measurements using a fluid such as toluene, commonly available with high quality and repeatability, rather than calibrated against a molar mass standard, because the latter technique depends on precise knowledge of concentration and refractive index increment of the standard in each specific solvent. As a consequence of the former calibration method, absolute rather than relative results will be obtained. The NanoStar, along with DYNAMICS or DYNAMICS Touch software, utilizes calibration by toluene when the quartz cuvette is installed.

  • Temperature Control: The instrument must provide temperature control of the cuvette from at least -10 °C to +120 °C with precision and accuracy of ±0.3 °C or better, thermal stability better than 0.01 °C and programmable ramp rates in the range of 0.01 °C to 15 °C per minute. The NanoStar utilizes a Peltier element with extensive thermal management to meet this requirement.

  • Measurement Range-The range of measurement of hydrodynamic radius by DLS must cover 0.2 – 2500 nm. The NanoStar accomplishes this by design and testing has proven that this range is addressed. The range of measurement of molar mass by SLS must cover 300 – 1,000,000 g/mol. The NanoStar accomplishes this by design and testing has proven that this range is addressed.The range of measurement of turbidity by SLS must cover 1 – 80 NTU with DYNAMICS Touch and above 80 NTU with DYNAMICS. The NanoStar accomplishes this by design and testing has proven that this range is addressed.

  • Wavelength- The instrument must utilize a red laser with wavelength longer than 650 nm in order to avoid exciting fluorescence which can overwhelm the DLS detector. The NanoStar utilizes a laser with wavelength of 658 nm to meet this requirement.

  • Connection to Wyatt MALS Instrument-The instrument must provide, or be upgradeable to provide, remote DLS detection in a Wyatt DAWN, miniDAWN or microDAWN multi-angle light scattering (MALS) detector’s flow cell by means of an optical fiber between the MALS read head and the DLS-SLS detector. The DLS data stream must be available to Wyatt’s ASTRA software so as to acquire DLS data from sample eluting in flowing chromatographic separations.



Date of Delivery: 30 Days ARO



Place of Delivery



Gaithersburg, MD 20878





The statutory authority for this sole source requirement is 41 U.S.C. 1901 (a) (1) as implemented by FAR 13.106-1 only one responsible source and no other supply of service will satisfy agency requirements. THIS IS NOT A REQUEST FOR PROPOSAL. All responsible sources that could provide this service may submit a capability statement along with a copy of a fully executed contract with the manufacturer to be considered by 10:00 am April 29, 2024. All required documents must be submitted via the NIAID electronic Simplified Acquisition Submission System (eSASS) website at https://esass.nih.gov. All vendors must register in the eSASS system to submit their documentation. Instructions on how to register /submit documents are included on the website. All responses received by the closing date of this synopsis will be considered by the Government. A determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government.




Attachments/Links
Contact Information
Contracting Office Address
  • 5601 FISHERS LANE, SUITE 3D11
  • BETHESDA , MD 20892
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Apr 19, 2024 09:52 am EDTSpecial Notice (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

..., systems engineering, testing and reliability, software engineering, testing and integration, information... and ...

DEPT OF DEFENSE

Bid Due: 5/17/2024

...for Measuring and Testing Electricity and Electrical Signals Place of Performance: Aberdeen Proving... ...

DEPT OF DEFENSE

Bid Due: 5/18/2024

...TESTING AND INSPECTION NAICS Code: 334519 - Other Measuring and Controlling Device Manufacturing ...

DEPT OF DEFENSE

Bid Due: 5/22/2024

...testing Instrument for Characterization of Environmental Soot Aggregates Vertical Cavity Surface... of Entangled ...

Department of Commerce

Bid Due: 1/22/2038

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only as a convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.