Crooked Run and Double Tollgate Pump Stations and ...

Agency: State Government of Virginia
State: Virginia
Type of Government: State & Local
Category:
  • 43 - Pumps and Compressors
  • Z - Maintenance, Repair or Alteration of Real Property
Posted: Apr 5, 2024
Due: Apr 23, 2024
Solicitation No: IFB 61916-5
Publication URL: To access bid details, please log in.
Views: Current Version ( 43 ) All Versions ( 598 )
Details


IFB-61916


  • Crooked Run and Double Tollgate Pump Stations and Force Mains
    i
  • Round:5
  • Status: Open
  • Time Left:17 days
  • Closing:4/23/24 2:00 PM
  • Issued:3/18/24 11:11 AM
  • Last Updated:4/5/24
  • Buyer:Connie Morrison-Henry

  • chenry@fcsa-water.com
  • 540-868-1061



IFB-61916


  • Crooked Run and Double Tollgate Pump Stations and Force Mains
    i
  • Round:5
  • Status: Open
  • Time Left:17 days
  • Closing:4/23/24 2:00 PM
  • Issued:3/18/24 11:11 AM
  • Last Updated:4/5/24
  • Buyer:Connie Morrison-Henry

  • chenry@fcsa-water.com
  • 540-868-1061

Actions
Solicitation only accepts paper responses.
  • Issued By:Frederick County Sanitation Authority
  • Opportunity Type:Invitation for Bids (IFB)
  • Category:Construction
  • Work Location:Frederick County Virginia
  • Website:www.frederickwater.com
  • Pre-Bid Conference:See solicitation documents for mandatory prebid/proposal conference/site visit.
  • Open Responses:See solicitation documents Public Opening information.
  • Summary:The Project includes the following Work:
    Crooked Run Pump Station and Force Main: Convert the existing Crooked Run Wastewater Treatment Plant into the Crooked Run Wastewater Pump Station. Work includes converting an existing sludge holding basin into a pump station wetwell, providing a suction lift pump station in a pre-cast concrete building with supporting electrical, mechanical and control work. Work includes providing multiple vaults and buried utility relocations for force mains, flow meters and comminutors at the Crooked Run Wastewater Treatment Plant Site. Work includes abandoning and decommissioning the existing Crooked Run Wastewater Treatment Plant. Work includes providing approximately 35,600 linear feet of 10-inch and 12-inch force main
    including multiple bore and jack and direction drill road crossings.

    Double Tollgate Pump Station and Force Main: Construct a new pump station and force main to serve the Double Tollgate region of Clarke County. Work includes providing a suction lift pump station in a pre-cast concrete building with supporting electrical, mechanical and
    control work. Work includes providing a flow meter and comminutor at the Double Tollgate Pump Station Site. Work includes providing approximately 2,400 linear feet of 6-inch force main including a bore and jack road crossing.
  • Round Information:ADDENDUM 1- Crooked Run and Double Tollgate Pump Stations and Force Mains- All files for the Addendum can be located at https://www.frederickwater.com/bid/addendum-1-crooked-run-and-double-tollgate-pump-stations-and-force-mains

Documents
Document Size Description Posted On Type
2024-03-01_Crooked Run & Double Tollgate IFC_Project Manual.pdf (13.96 MB) CROOKED RUN AND DOUBLE TOLLGATE PUMP STATION AND FORCE MAIN PROJECT DOCUMENTS 3/18/24 RFx Document
2024-03-01_Double Tollgate IFC_Drawings.pdf (21.38 MB) CROOKED RUN AND DOUBLE TOLLGATE PUMP STATION AND FORCE MAIN PROJECT DOCUMENTS 3/18/24 RFx Document
2024-03-15_Crooked Run IFC_Drawings.pdf (53.82 MB) CROOKED RUN AND DOUBLE TOLLGATE PUMP STATION AND FORCE MAIN PROJECT DOCUMENTS 3/18/24 RFx Document
FW CR DT Addendum 1 Rev2.pdf (12.16 MB) ADDENDUM 1- Crooked Run and Double Tollgate Pump Stations and Force Mains 4/5/24 RFx Document
Follow B2B ActivityUnfollow B2B ActivityAdd B2B Posting
  • Rocket Shop LLC offers mobile welding certified to ASME standards and mechanical services. Feel free to contact us.
  • Chris Salmon of Rocket Shop LLC
  • Chris@rocketshopllc.com
  • 240-337-2104
  • 4/5/24 2:37 PM
  • B2B Follow ×
    Enter Email Address:
    CloseSubmit
    B2B Unfollow ×
    Enter Email Address:
    CloseSubmit
    Add B2B Posting ×
    Contact Name:
    Company Name:
    Email Address:
    Phone Number:
    SWaM Certifications:

    Micro Business

    Small Business

    Minority Owned Business

    Women Owned Business

    Service Disabled Veteran Owned

    Employment Service Org
    Message:
    CloseSubmit
    Daily notification on new contract opportunities

    With GovernmentContracts, you can:

    • Find more opportunities and win more business
    • Receive daily alerts for all new bid opportunities
    • Get contract opportunities matched to your business
    ONE WEEK FREE TRIAL

    See also

    ...BID/PROPOSAL # DESCRIPTION DUE DATE RFP#09-62 WASTEWATER OPERATOR TRAINING SERVICES 01/23/3009...

    City of Charlottesville

    Bid Due: 1/23/2030

    ...WASTEWATER CONVEYANCE SYSTEM MODIFICATIONS GMP 2- PUMP STATION (CMAR) Project i Round:2 Status: ...

    State Government of Virginia

    Bid Due: 5/09/2024

    ...ADMN24000312 | Engineering Services - Utilities Wastewater and Water Chesterfield County...

    Cesterfield Country

    Bid Due: 5/10/2024

    ...WASTEWATER CONVEYANCE SYSTEM MODIFICATIONS GMP 2- PUMP STATION (CMAR) Project i Round:3 Status: ...

    State Government of Virginia

    Bid Due: 5/09/2024

    * Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only as a convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.