Bunten Road Park Improvement Project

Location: Georgia
Posted: Dec 23, 2025
Due: Jan 22, 2026
Agency: City of Duluth
Type of Government: State & Local
Category:
  • Y - Construction of Structures and Facilities
  • Z - Maintenance, Repair or Alteration of Real Property
Publication URL: To access bid details, please log in.
Description Opening Date/Time Closing Date/Time


Bunten Road Park Improvement Project


Architectural Plans



December 10, 2025
:


January 22, 2026
11:00
AM

Attachment Preview

BUNTEN ROAD PARK
IMPROVEMENT PROJECT
3180 BUNTEN ROAD
DULUTH, GA 30096
VICINITY MAP
SITE
AREA MAP
GWINNETT COUNTY FIRE MARSHAL INSPECTIONS ARE TO BE SCHEDULED ONLINE AT:
GwinnettZIP.com
-50% = Inspections of vertical penetrations.
-80% = Inspections of any fire rated partitions, floor or ceiling, ceiling cover up.
-100% = Final inspection, all systems and equipment are installed and operational,
Any inspection requests made after 2:00 pm will be scheduled for the next business day.
SEPARATE SUBMITTALS AND REVIEWS BY FIRE PLAN REVIEW FOR:
__ Fire Sprinkler
__ Fire Alarm Systems
__ Kitchen Hoods
__ Fire Suppression Systems
__ Rack Storage (Product height over 12 feet)
__ Storage and/or use of Hazardous Materials
1. SIGNS ARE NOT APPROVED WITHIN THE SCOPE OF THIS BUILDING PERMIT. A SEPARATE SIGN
LOCATION PERMIT IS REQUIRED FOR EACH SIGN
2. SMOKING IS PROHIBITED IN ALL ENCLOSED PUBLIC PLACES AND IN ALL ENCLOSED AREAS WITHIN
PLACES OF EMPLOYMENT IN ACCORDANCE WITH COUNTY CLEAN INDOOR AIR ORDINANCE.
REVISION HISTORY
NO.
DATE
DESCRIPTION
1 10/16/2025
COUNTY
COMMENTS
SHEETS
G-001, A-101
DRAWING INDEX
SHEET NUMBER
GENERAL
SHEET NAME
G-001
G-002
ARCHITECTURAL COVER SHEET
GENERAL NOTES
ARCHITECTURAL
SHEET NUMBER
SHEET NAME
D-101
EXISTING CONDITIONS & DEMOLITION FLOOR PLANS
A-101
NEW FLOOR PLAN, WALL SECTION, SCHEDULES &
DETAILS
SCOPE OF WORK
ADDITION OF CONCRETE BLOCK PRIVACY WALLS AROUND RESTROOM ENTRANCE DOORS, RELOCATION OF WOMEN'S
RESTROOM ENTRANCE DOOR.
SITE
BLDG
JURISDICTION
BUILDING REVIEW:
CTIYOFDULUTH
3167 MAIN STREET
DULUTH, GEORGIA 30096
PH: 770.476.3434
FIRE PLAN REVIEW:
GWNINETTCOUNTYDEPOT.FPLANNNIG&DEVELOPMENT
FIRE PLAN REVIEW
ONE JUSTICE SQUARE
446 WEST CROGAN STREET, SUITE 150
LAWRENCEVILLE, GEORGIA 30046
PH: 678.518.6000 FAX: 678.518.6144
CODES/STANDARDS & CLASSIFICATIONS
2018 INTERNATIONAL BUILDING CODE, WITH 2020 GEORGIA STATE AMENDMENTS
2018 INTERNATIONAL MECHANICAL CODE, WITH 2020 GEORGIA STATE AMENDMENTS
2018 INTERNATIONAL FUEL GAS CODE, WITH 2020 GEORGIA STATE AMENDMENTS
2018 INTERNATIONAL PLUMBING CODE, WITH 2020 GEORGIA STATE AMENDMENTS
2020 NFPA NATIONAL ELECTRIC CODE
2018 INTERNATIONAL FIRE CODE, WITH LATEST STATE AMENDMENTS
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
NFPA 101, LIFE SAFETY CODE 2024 EDITION. (AMENDED BY 120-3-3) 1
2015 INTERNATIONAL ENERGY CONSERVATION CODE , WITH 2020 GEORGIA STATE AMENDMENTS
2018 INTERNATIONAL EXISTING BUILDING CODE WITH 2015 GEORGIA STATE AMENDMENTS
2015 GWINNETT COUNTY CONSTRUCTION CODE
2012 GWINNETT COUNTY ORDINANCE FOR FIRE PROTECTION AND LIFE SAFETY
CURRENT EDITION OF THE NFPA CODES AND STANDARDS AS ADOPTED AND MODIFIED BY THE STATE FIRE MARSHAL
CURRENT ADOPTED OCGA 120-3-3 GEORGIA MINIMUM FIRE SAFETY STANDARDS 1
PROJECT INFORMATION
NAME OF DEVELOPMENT:
DEVELOPMENT LOCATION:
BUNTEN ROAD PARK
3180 BUNTEN ROAD DULUTH, GEORGIA
NAME OF OWNER:
OWNER ADDRESS:
CITY OF DULUTH
3167 MAIN STREET
DULUTH, GA 30096
BUILDING AREA:
NUMBER OF BUILDINGS:
NUMBER OF STORIES:
BLDG HGT PER CODE:
OCCUPANCY CLASSIFICATION:
CALCULATED LOAD FOR WATER CLOSETS:
CALCULATED LOAD FOR LAVATORIES:
OCCUPANCY LOAD CALCULATIONS:
CONSTRUCTION TYPE:
GROSS BUILDING AREA:
348 SQUARE FEET
ONE
ONE
EXISTING
(U) UTILITY & MISCELLANEOUS
EXISTING
EXISTING
N/A
IIIB - NOT SPRINKLERED, NON-FIRE ALARMED
348 SQUARE FEET
10/16/2025
1
COUNTY COMMENTS
GENERAL NOTES:
FIRE EXTINGUISHERS REQUIRED
PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA
STANDARD NO. 10. ABC. LOCATION AND ARRANGEMENT OF THE FIRE
EXTINGUISHERS WILL BE DETERMINED BY AN INSPECTOR OF THE FIRE
MARSHAL'S OFFICE PRIOR TO FINAL INSPECTION.
FIRE EXTINGUISHERS IN BUSINESS & MERCANTILE OCCUPANCIES SHALL
BE LOCATED PER REQUIREMENTS OF NFPA 10. THE SIZE SHALL BE A
MINIMUM OF TYPE A 10 TW0 (2) ARE REQUIRED AND SHALL BE INSTALLED
AT A MAXIMUM OF 48" ABOVE THE FINISHED FLOOR TO THE TOP OF THE
HANDLE.
EGRESS LIGHTING
EMERGENCY EGRESS LIGHTING MUST PROVIDE A MINIMUM 1-FOOT
CANDLE UNINTERRUPTED LIGHT SOURCE ALONG THE PATH OF EGRESS.
IF LESS THAN 3 SEPARATE LIGHTING CIRCUITS ARE PROVIDED, DEDICATED
CIRCUITS FOR EMERGENCY LIGHTING ARE NOT PERMITTED. THEY SHALL
BE CONNECTED TO THE LIGHTING CIRCUIT BREAKER THE AREA THEY
SERVE. NFPA 70, CHAPTER 7, SECTION 700-12(E). DEDICATED CIRCUITS
FOR EXIT LIGHTING ARE NOT PERMITTED. THEY SHALL BE CONNECTED TO
THE LIGHTING CIRCUIT BREAKER IN THE AREA THEY SERVE. NFPA 70,
CHAPTER 7.
LABELING
ALL UTILITY METERS, DISCONNECT SWITCHES, FRONT & REAR DOORS
MUST BE MARKED WITH CONTRASTING LETTERS & NUMBERS TO INDICATE
THE TENANT SPACE THEY SERVE.
EXIT LIGHTING
ALL EXIT LIGHTS & EMERGENCY LIGHTS SHALL HAVE A MINIMUM 90
MINUTE BATTERY LIFE.
SMOKE DETECTORS
ANY HVAC EQUIPMENT PRODUCING MORE THAN 2000 CFM AIR VOLUME
MUST BE EQUIPPED WITH AN AUTOMATIC SMOKE DETECTOR WITHIN THE
DUCTWORK THAT IS CAPABLE OF SHUTTING DOWN THE UNIT IN THE
EVENT OF FIRE. SMOKE DETECTORS MUST BE WIRED TO A VISUAL
STROBE, AS WELL AS PRODUCE AN AUDIBLE ALARM SO AS TO ALERT THE
BUILDING OCCUPANTS OF FIRE OR SMOKE DETECTED.
ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE CODES.
COORDINATION OF ALL DISCIPLINES IS THE RESPONSIBILITY OF THE
GENERAL CONTRACTOR. IF THE CONTRACTOR FINDS ANY DISCREPANCIES
IN THE DOCUMENTS SUCH THAT MUST BE REPORTED IMMEDIATELY TO
THE ARCHITECT. TYPICALLY DOCUMENTS INCLUDE A SPECIFICATION
MANUAL. CONTRACTOR TO REVIEW THE SPECIFICATIONS FOR THE
PROJECT.
CONTRACTOR MUST FIELD VERIFY ALL DIMENSIONS AT PROJECT.
CONTRACTOR SHOULD NOT SCALE OFF OF DRAWINGS. CONTRACTOR
NEEDS TO FIELD VERIFY EXISTING CONDITIONS TO CONFIRM DRAWINGS
ARE ACCURATE. IF THE CONTRACTOR FINDS DISCREPANCIES BETWEEN
FIELD CONDITIONS AND DOCUMENTS THE CONTRACTOR MUST
IMMEDIATELY CONTACT THE ARCHITECT.
DOORS AND ACCESSIBILITY:
CONTRACTOR SHALL FOLLOW THE U.S. DEPARTMENT OF JUSTICE, 2010
AMERICANS WITH DISABILITIES ACT (A.D.A.) STANDARDS FOR ACCESSIBLE
DESIGN. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CLEAR AREAS AND
ANY A.D.A. REQUIREMENTS BEFORE BEGINNING WORK. CONTRACTOR
MUST IMMEDIATELY CONTACT THE ARCHITECT IF DISCREPANCIES ARE
FOUND.
DOORS SHALL MEET THE REQUIREMENTS OF THE NFPA 101 LIFE SAFETY
CODE, CHAPTER 7.
THE FLOOR LEVEL SHALL BE THE SAME ON BOTH SIDES OF THE DOOR (NO
MORE THAN 1/2" DROP). THE ELEVATION SHALL BE MAINTAINED FOR A
DISTANCE AT LEAST EQUAL TO THE WIDTH OF THE WIDEST LEAF OF THE
DOORS. NFPA 101 LIFE SAFETY CODE, CHAPTER 7.
EXIT DOORS SHALL NOT BE SUBJECT TO THE USE OF A KEY OR REQUIRE
SPECIAL KNOWLEDGE TO OPERATE, NFPA 101 LIFE SAFETY CODE,
CHAPTER 7, LATEST EDITION.
DOORS/HARDWARE, HANDLES, PULLS, LATCHES, LOCKS, AND OTHER
OPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT
IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT
GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE.
LEVER-OPERATED MECHANISMS, PUSH-TYPE MECHANISMS, AND
U-SHAPED HANDLES ARE ACCEPTABLE DESIGNS. THESE TYPES SHALL BE
SUPPLIED PER THE ADA STANDARDS FOR ACCESSIBLE DESIGN. TO THE
BEST OF OUR KNOWLEDGE THIS INFORMATION ON THESE DRAWINGS
COMPLY WITH ADA. CONTRACTOR MUST VERIFY BEFORE PURCHASE OF
DEVICES.
TYPICAL MINIMUM MANEUVERING CLEARANCES ON THE PULL SIDE OF
DOOR SHALL BE A MINIMUM OF 18". PER THE ADA STANDARDS FOR
ACCESSIBLE DESIGN. MINIMUM MANEUVERING CLEARANCES IN THE PUSH
SIDE OF THE DOOR SHALL BE A MINIMUM OF 12" IF THE DOOR HAS A
CLOSER AND A LATCH. PER THE ADA STANDARDS FOR ACCESSIBLE
DESIGN. THE TOPS OF ACCESSIBLE TABLES AND COUNTERS SHALL BE
FROM 28 INCHES TO 34 INCHES ABOVE THE FINISHED FLOOR OR GROUND
PER ADA STANDARDS FOR ACCESSIBLE DESIGN.
DRINKING FOUNTAINS:
IF APPLICABLE, WHERE ONLY ONE DRINKING FOUNTAIN IS PROVIDED ON A
FLOOR, THERE SHALL BE A DRINKING FOUNTAIN WHICH IS ACCESSIBLE TO
INDIVIDUALS WHO USE WHEEL CHAIRS IN ACCORDANCE WITH 2010 ADA,
AND ONE ACCESSIBLE TO THOSE WHO HAVE DIFFICULTY BENDING OR
STOOPING. THIS CAN BE ACCOMMODATED BY USE OF A "HI-LO"
FOUNTAIN. ADVISORY 602.6 WATER FLOW. THE PURPOSE OF REQUIRING
THE DRINKING FOUNTAIN SPOUT TO PRODUCE A FLOW OF WATER 4
INCHES (100 MM) HIGH MINIMUM IS SO THAT A CUP CAN BE INSERTED
UNDER THE FLOW OF WATER TO PROVIDE A DRINK OF WATER FOR AN
INDIVIDUAL WHO, BECAUSE OF A DISABILITY, WOULD OTHERWISE BE
INCAPABLE OF USING THE DRINKING FOUNTAIN.
GENERAL:
ALL CONCEALED WOOD TO BE FIRE RETARDANT UNLESS IT MEETS WOOD
BLOCKING EXCEPTION IN CODE.
CONTRACTOR SHALL INSTALL WOOD BLOCKING FOR ALL WALL HUNG
DEVICES SUFFICIENT TO MEET LOCAL CODES.
INSULATING MATERIALS INSTALLED IN BUILDING OF ANY TYPE OF
CONSTRUCTION SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN
25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 450 AS
DETERMINED IN ACCORDANCE WITH ASTM E84.
SIGNAGE IS NOT PERMITTED WITH THESE DOCUMENTS. A SEPARATE
PERMIT FOR SIGNS MUST BE SUBMITTED.
ARCHITECTURAL ABBREVIATIONS
PLEASE REFER TO ENGINEERING DRAWINGS FOR ENGINEERING
AABBREVIATIONS A
F
F
M
A.C.T.
A.F.F
A.H.U
ALT.
ALUM.
ANOD
APPROX.
ARCH.
ASTM
AUX.
B
B/
B.F.F.
BKBD
BLDG.
C
C.I.P.
C.J.
C/L
CLG.
CLR.
C.M.
C.M.U.
CNT.
C.O.
CONC.
CONT.
CPT.
C.T.
D
DBL.
DIA.
DIV.
DN.
DR.
D.S.
DW.
D.W.
DWG.
DWGS.
E
EA
EF.
ELEC.
ELEV., EL
E.M.S.
E.P.D.M
EQ.
EQUIP.
E.W.
E.W.H.
EX., EXIST.
EXP.
EXT.
ACOUSTICAL CEILING TILE
ABOVE FINISH FLOOR
AIR HANDLING UNIT
ALTERNATE
ALUMINUM
ANODIZED
APPROXIMATELY
ARCHITECTURAL
AMERICAN SOCIETY FOR
TESTING MATERIAL
AUXILIARY
B
BOTTOM OF
BOTTOM OF FINISH FLOOR
BACKBOARD
BUILDING
C
CAST IN PLACE
CONTROL JOINT
CENTERLINE
CEILING
CLEAR
COFFEE MAKER
CONCRETE MASONRY UNIT
COUNTER
CASED OPENING
CONCRETE
CONTINUOUS
CARPET
CERAMIC TILE
D
DOUBLE
DIAMETER
DIVISION
DOWN
DOOR
DOWNSPOUT
DISHWASHER
DOMESTIC WATER
DRAWING
DRAWINGS
E
EACH
EXHAUST FAN
ELECTRIC, ELECTRICAL
ELEVATION
ENERGY MANAGEMENT SYSTEM
ETHYLENE PROPYLENE
DIENE MONOMER
EQUAL
EQUIPMENT
EACH WAY
ELECTRIC WATER HEATER
EXISTING
EXPANSION
EXTERIOR
*F
F.D.
F.D.C.
F.E.
F.E.C.
F.F.
FT.
F.V.
F.R.T.
FAHRENHEIT
FLOOR DRAIN
FIRE DEPARTMENT CONNECTOR
FIRE EXTINGUISHER
FIRE EXTINGUISHER
CABINET
MAX.
MECH.
MFR.
MICRO.
MIN.
MISC.
FINISH FLOOR
MM.
FEET
M.O.
FIELD VERIFY
MTD.
FIRE RETARDANT TREATED
MTL.
G
G
GA.
GALV.
G.C.
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GFCI.
GROUND FAULT
CURRENT INTERUPTER
GL
GLASS, GLAZING
G.W.B, GYP.BD. GYPSUM WALL BOARD
N
N/A
NEG.
N.F.W.H.
N.I.S.
NO.
H
HC.
HDWR.
HM
HORIZ.
HR.
I
ID.
I.M.
IN.
INCAND.
INSUL.
J
JT.
K
K.
KO.
KW
L
LAM.
LAV.
LB.
LF.
L.S.D.
H
HANDICAPPED
HARDWARE
HOLLOW METAL
HORIZONTAL
HOUR
I
INSIDE DIMENSION
ICE MAKER
INCHES
INCANDESCENT
INSULATION
J
JOINT
K
KIP
KNOCK OUT
KILOWATT
L
LAMINATE
LAVATORY
POUND
LINEAR FOOT
LIQUID SOAP DISPENSER
O
O.A.
O.C.
O.D.
O.H.
OPNG.
OPP.
OPP. HD
P
P.A.
PAR.
PERP.
PL.
P. LAM.
PLY. WD.
PNL.
POS.
PREFAB.
PREFIN.
P.S.I.
P.S.F.
P.T.
PVC.
PVMT.
Q
-
M
MAXIMUM
MECHANICAL
MANUFACTURER
MICROWAVE
MINIMUM
MISCELLANEOUS
MILLIMETER
MASONRY OPENING
MOUNTED
METAL
N
NOT APPLICABLE
NEGATIVE
NON-FREEZE WALL
HYDRANT
NOT IN SCOPE
NUMBER
O
OVERALL
ON CENTER
OUTSIDE DIMENSION OR
OUTSIDE DIAMETER
OVERHEAD
OPENING
OPPOSITE
OPPOSITE HAND
P
PUBLIC ADDRESS
PARALLEL
PERPENDICULAR
PLATE
PLASTIC LAMINATE
PLYWOOD
PANEL
POSITIVE
PRE-FABRICATED
PRE-FINISHED
POUND PER SQUARE INCH
POUND PER SQUARE FOOT
PRESURE TREATED
POLYVINYL CHLORIDE
PAVEMENT
Q
-
R
R.
R.D.
REF.
REINF.
REQD.
R.L.
R.O.
R.T.U.
R.V.
S
SCH.
SGL.
SH. ROD
SHT.
SIM.
S.O.G.
S.S.
STD.
STL.
STRUCT.
T
T/C
TECH
TEL
TEMP.
T.O.
TR.
TSTAT.
TYP.
U
U.N.O.
UTIL.
V
V.C.T.
VEND.
V.I.F.
VERT.
V.T.R.
V.W.C.
W
W/
W.C.
W.H.
WHSE.
WP.
W.R.
W.W.F.
MATERIAL INDEX
R
RADIUS
ROOF DRAIN
REFRIGERATOR
REINFORCE, REINFORCING
REQUIRED
RAIN LEADER
ROUGH OPENING
ROOF TOP UNIT
ROOF VENT
S
SCHEDULE
SINGLE
SHOWER ROD
SHEET
SIMILAR
SLAB ON GRADE
STAINLESS STEEL
STANDARD
STEEL
STRUCTURE, STRUCTURAL
T
TOP OF CURB
TECHNICAL
TELEPHONE
TEMPERATURE
TOP OF
TRANSITION STRIP
THERMOSTAT
TYPICAL
U
UNLESS NOTED OTHERWISE
UTILITY
V
VINYL COMPOSITION TILE
VENDING MACHINE
VERIFY IN FIELD
VERTICAL
VENT THROUGH ROOF
VINYL WALL COVERING
W
WITH
WATER CLOSET/
WATER COOLER
WATER HEATER
WAREHOUSE
WEATHER PROOF
WATER RESISTANT
WELDED WIRE FABRIC
FINISH RATINGS
EARTH
GRAVEL
GROUT OR
SURFACE
CONCRETE
CAST-IN-PLACE
CONCRETE
CUT STONE
WOOD -
ROUGH
WOOD - FINISH
WOOD
BLOCKING
STEEL
PLYWOOD
GYPSUM
INSULATION - BATT
OR LOOSE
RIGID INSULATION
EXTERIOR
INSULATION
FINISH SYSTEM
BRICK
MINIMUM WALL FINISH
CLASS "M"
MINIMUM ROOF FINISH
CLASS USE GROUP
EXITS &
EXIT ACCESS
PASSAGEWAYS CORRIDORS
A or B
A or B
A or B
A or B
ROOMS
A or B
A or B
GENERAL LEGEND
1
2
A
B
4
A101
1
1' - 0" A
1
A101
2A
A101
A
1
3
A101
NAME
101
X-1
1' - 10 1/2"
COLUMN LINE INDICATOR
FACE OF WALL INDICATOR
DETAIL INDICATOR
DETAIL NUMBER
SHEET NUMBER
DOOR NUMBER, REFER
TO SCHEDULE
CEILING MATERIAL FINISH
CEILING HEIGHT
EXTERIOR ELEVATION INDICATOR
DETAIL NUMBER
SHEET NUMBER
INTERIOR ELEVATION INDICATOR
DETAIL NUMBER
SHEET NUMBER
WALL/PARTITION TYPE
WINDOW TYPE,
REFER TO SCHEDULE
ENLARGED PLAN/DETAIL INDICATOR
DETAIL NUMBER
SHEET NUMBER
ROOM NAME AND NUMBER
EXTERIOR FINISH MATERIAL
DIMENSION LINE
NOTE: DIMENSIONS ARE TAKEN FROM FINISHED
FACE UNLESS OTHERWISE NOTED.
NEW OPENING IN
SOFFIT FOR NEW
LIGHT FXTURE
EXISTING LIGHT
TO REMAIN
EXISTING LIGHT
TO REMAIN
EXISTING
LIGHTS TO
REMAIN
NEW OPENING IN
SOFFIT FOR NEW
LIGHT FIXTURE
EXISTING
LIGHTS TO
REMAIN
EXISTING LIGHT
TO REMAIN
EXISTING LIGHT
EXISTING LIGHT
EXISTING
LIGHTS TO
REMAIN
EXISTING
LIGHTS TO
REMAIN
EXISTING LIGHT
EXISTING
LIGHTS TO
REMAIN
EXISTING
LIGHTS TO
REMAIN
EXISTING LIGHT
TO REMAIN
EXISTING ROOF
OVERHANG TO
REMAIN
4 DEMOLITION REFLECTED CEILING PLAN
D-101 SCALE: 1/4" = 1'-0"
EXISTING LIGHT
EXISTING ROOF
OVERHANG
2 EXISTING CONDITONS REFLECTED CEILING PLAN
D-101 SCALE: 1/4" = 1'-0"
6" BLOCK WALL
REMOVE EXISTING
ASPHALT FOR NEW
FOOTING
5
D-101
RETROFIT LINTEL DETAIL
SCALE: N.T.S.
NOTE:
1) ALL PLATES AND ANGLES TO RECEIVE
(2) COATS PAINT
EXISTING TELEPHONE CABINET
TO BE REMOVED; CONTRACTOR
TO PATCH AND REPAIR BLOCK
ONCE TELEPHONE CABINET IS
REMOVED
EXISTING
SIDEWALK TO
BE REMOVED
MEN
RESTROOM
12'-4" X 6'-7"
REFER TO CIVIL DWGS FOR
ADDITONAL INFORMATION
TELEPHONE CONDUIT TO BE
REMOVED AND CUT OFF AT
SOFFIT; CONTRACTOR TO
PATCH AND REPAIR SOFFIT
EXISTING HOSE
BIBB TO REMAIN
3'-4" 8"
WOMEN
RESTROOM
12'-4" X 6'-7"
REMOVE EXISTING
BLOCK FOR NEW
MASONRY OPENING
HM DOOR, TYP.
8" CONCRETE
BLOCK WALL TYP.
TELEPHONE
DRYER
DRYER
WOMEN
RESTROOM
MEN
RESTROOM
5'-0"
5'-0"
1'-7" 1'-5" 4'-4"
ELETRICAL
METER
EXISTING
ELETRICAL PANEL
5'-8"
6'-0"
8" CONCRETE
BLOCK WALL TYP.
5'-8"
EXISTING
SIDEWALK TO
REMAIN
3 DEMOLITION FLOOR PLAN
D-101 SCALE: 1/4" = 1'-0"
8'-0"
3'-4"
M.O.
18'-8"
7'-4"
EXISTING
SIDEWALK
EXISTING ROOF
OVERHANG
1
D-101
EXISTING CONDITIONS FLOOR PLAN
SCALE: 1/4" = 1'-0"
GC TO FIELD VERIFY DIMENSIONS MATCH PLAN.
CONTACT ARCHITECT IF DIMENSIONS ARE DIFFERENT.
NEW TOP OF 4" SLAB TO
BE FLUSH WITH EXISTING
6X6 - W1.4 X W1.4 WWF
NEW 15 MIL VAPOR
BARRIER AND
GRANULAR BASE
------X------X------X------X------X---
#4 x 1'-0" @ 24" O.C. DRILL 6"
INTO EXISTING SLAB
CONT. MTL DRIP EDGE
NOTES:
1. G.C. TO REMOVE PORTION OF EXISTING
WALL TO INSTALL NEW DOORS. G.C. MUST
SHORE UP BLOCK PER OSHA STANDARDS
AND INSTALL STL ANGLE PER STRUCT DWGS.
2. G.C. TO VERIFY NEW INSTALLATION IS WATER
TIGHT AND FLASHED PER MANUF.
RECOMMENDATIONS.
EXISTING CONCRETE
BLOCK WALL TO BE
PAINTED
PAINTED STEEL PLATE -
REFER TO STRUCTURAL DWGS.
CONT. SEALANT BOTH
SIDES ALONG
PERIMETER OF FRAME
NEW HOLLOW METAL FRAME
EXISTING
LIGHT
NEW DOWNLIGHT;
REFER TO RCP
LEGEND
EXISTING GRADE
NEW COMPACTED EARTH
6 NEW SLAB CONNECTION DETAIL
A-101 SCALE: 1" = 1'-0"
EXTERIOR
5 HEAD DETAIL
A-101 SCALE: 1-1/2" = 1'-0"
INTERIOR
CONCRETE NOTES:
1) ALL CONCRETE WORK INCLUDING FORMING, REINFORCING, MIXING, PLACING AND
CURING SHALL BE DONE IN ACCORDANCE WITH THE ACI MANUAL OF CONCRETE
PRACTICE INCLUDING 'BUILDING CODE REQUIREMENTS FOR CONCRETE'. ACI 301,
LATEST EDITIONS.
2) ALL CONCRETE SHALL ATTAIN A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF
f'c = 3,000 PSI FOR FOUNDATIONS, FOOTINGS AND STEM WALLS.
f'c = 4,000 PSI FOR SLABS, PIERS, COLUMNS AND BEAMS.
3) MIX DESIGNS SHALL BE IN ACCORDANCE WITH METHOD 1 OR METHOD 2 OF ACI 301-05.
4) ALL CONCRETE SHALL HAVE A MAXIMUM WATER-CEMENT RATIO OF 0.50
5) CONCRETE SHALL ARRIVE AT THE JOBSITE WITH A SLUMP OF 3" TO 5".
6) CONCRETE SHALL BE VIBRATED INTO FORMS WHILE PLACING WITHOUT
OVER-VIBRATING. REINFORCING SHALL HAVE MINIMUM CONCRETE COVER OF -
CONCRETE EXPOSED TO SOIL = 3"
CONCRETE EXPOSED TO AIR = 2"
7) CONCRETE TEST REPORTS SHALL BE MADE AVAILABLE TO JOB SITE FOR REVIEW BY
INSPECTOR.
8) DESIGN OF CONCRETE STRUCTURAL ELEMENTS INCLUDING WALLS, FORMED SLABS,
BEAMS AND COLUMNS IS IN ACCORDANCE WITH ACI 318-14.
9) PLACE A 15 MIL POLYETHYLENE MOISTURE BARRIER (WITH JOINTS LAPPED NOT LESS
THAN 6 INCHES) DIRECTLY BENEATH ALL INTERIOR CONCRETE SLABS OR GRADES.
EXTERIOR
4
A-101
EXISTING ROOF
JOINTS IN CONCRETE NOTES:
1) CONSTRUCTION AND/OR CONTROL JOINTS SHALL BE MADE AS DETAILED ON THE
DRAWINGS. SAW-CUT CONTROL JOINTS SHALL BE INSTALLED WITHIN 12 HOURS OF
CONCRETE PLACEMENT.
2) CONSTRUCTION AND/OR CONTROL JOINTS FOR SLAB-ON-GRADE CONSTRUCTION
SHALL BE LOCATED ON COLUMN LINES.
EXISTING FASCIA AND
SOFFIT TO BE PAINTED
8" BOND BEAM
WITH (1) #5 CONT.
SLOPE
4" CAP BLOCK
8" (NOM) CONCRETE
SPLIT FACE BLOCK
WALL, GROUT FILL
EVERY@ 24" O.C. PER
REBAR LOCATION
NEW HOLLOW METAL
DOOR & FRAME TO BE
PAINTED
WALL BEYOND
HOLLOW METAL DOOR
WEATHER STRIP
ALUM. THRESHOLD
FINISH FLOOR
INTERIOR
SECURE TO SLAB PER
MANUFACTURER'S
INSTRUCTIONS
DTL. AT METAL
THRESHOLD
SCALE: 3" = 1'-0"
5
A-101
#5 AT 24" O.C.
EXTERIOR
RESTROOM
SOLID GROUT
FILL, TYP.
NEW CONCRETE,
REFER TO CIVIL DWGS.
NOTE:
MINIMUM CONCRETE
COVER FOR ALL
F.F.E.
0' - 0"
REINFORCING = 3"
#5 AT 24" O.C.
#5 REBAR AT 24" O.C.
DOWELS AT VERT. BARS.
FILL CELLS AT ANCHORS
(6) #5 CONT.
(2) COATS ELASTOMERIC PAINT,
REFER TO FINISH SCHEDULE ON
A-102 FOR COLOR
DOOR THRESHOLD
EXPANSION JOINT
CONCRETE PAD, SLOPE
AWAY FROM BUILDING
NEW 4,000 PSI 4"
CONCRETE SLAB WITH
WWF, REFER TO 6/A-101
4
A-101
EXISTING CONC. SLAB
AND TURNDOWN
3'-0"
2
A-101
COMPACTED SUBGRADE PER
GEOTECHNICAL REPORT
WALL SECTION
SCALE: 3/4" = 1'-0"
NEW DOWNLIGHT;
REFER TO RCP LEGEND
EXISTING LIGHT
REFLECTED CEILING PLAN LEGEND
SYMBOL
DESCRIPTION
LIGHTOLIER BY SIGNIFY; FD 6R 11 Z10 SCT U W
NOTES:
EXISTING BRANCH CIRCUIT SERVING EXISTING DOWNLIGHTS TO BE DEMOLISHED
AND REUSED AND EXTENDED TO SERVE NEW DOWNLIGHT LUMINARIES.
PROVIDE NEW CONDUIT AND WIRE AS REQUIRED. NEW CONDUIT AND WIRE TO
MATCH EXISTING.
TOTAL LOAD OF NEW LUMINARIES IS FIELD-SELECTABLE.
G.C.TO SET CCT SWITCH TO MATCH NEARBY EXTERIOR AND SITE LUMINARIES.
EXISTING
LIGHTS, NIS
EXISTING
LIGHTS, NIS
EXISTING
LIGHTS, NIS
EXISTING LIGHT
3 REFLECTED CEILING PLAN
A-101 SCALE: 1/4" = 1'-0"
NEW 8" CONCRETE
BLOCK WALL, MATCH
EXISTING
MEN'S
RESTROOM
SIGN
NEW CONCRETE
SIDEWALK, REFER
TO CIVIL DWGS
5'-4"
MEN'S
RESTROOM
SIGN
MEN
RESTROOM
EX2
EXISTING TO REMAIN
EXISTING
URINAL TO
REMAIN
1
WOMEN'S
RESTROOM
SIGN
2
A-101
6'-8"
1
WOMEN
RESTROOM
EXISTING TO REMAIN
NEW 8" CONCRETE
BLOCK WALL, MATCH
EXISTING
WOMEN'S
RESTROOM
SIGN
6
A-101
INFILL DOOR OPENING
WITH NEW BLOCK TO
MATCH EXISTING. GET
BLOCK
MANUFACTURER &
TYPE FROM CITY.
NEW
SAFETY
MIRROR
NEW CONCRETE
SIDEWALK, REFER
TO CIVIL DWGS
6
A-101
EX1
1
A-101
NEW KEY ACCESS FOB; CONTRACTOR TO
RUN POWER TO DOOR STRIKE AND NEW
KEY FOB, REFER TO SHEET A-102 FOR
SPECIFICS
NEW FLOOR PLAN
SCALE: 1/4" = 1'-0"
10/16/2025 1 COUNTY COMMENTS
EXISTING LIGHT
12"
A MEN'S DOOR MOUNTED SIGNAGE
NTS
6"
MEN'S
RESTROOM
B MEN'S WALL MOUNTED SIGNAGE
NTS
9" MIN.
CENTER TACTILE CHAR.
EQ. EQ.
LATCH SIDE
MEN'S
RESTROOM
VERTICAL DIMENSIONS FROM TOP
OF FINISHED FLOOR
C TYPICAL DIMENSIONS
NTS
12"
D WOMEN'S DOOR MOUNTED SIGNAGE
NTS
6"
9" MIN.
CENTER TACTILE CHAR.
EQ. EQ.
LATCH SIDE
WOMEN'S
RESTROOM
WOMEN'S
RESTROOM
E WOMEN'S WALL MOUNTED SIGNAGE
NTS
VERTICAL DIMENSIONS FROM TOP
OF FINISHED FLOOR
F TYPICAL DIMENSIONS
NTS
SIGNAGE NOTES:
1. SIGNS PROVIDED BY G.C. TO COMPLY WITH CA TITLE 24 REQUIREMENTS FOR ADA SIGNAGE AND WILL BE
USED IN ALL STORES. SIGNS TO INSTALLED BY G.C.
COMPLIANCE SIGNS.COM ADA RESTROOM: RRE-120_DCTS_WHTONCHGRY PAIRED SET, SIZE: 12" CIRCLE / 9"H X
6"W. WHITE LETTERS ON CHARCOAL GRAY BACKGROUND
2. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL BE INSTALLED
ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE TO THE LATCH
SIDE OF THE DOOR, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT
WALL. TACTILE CHARACTERS SHALL BE MOUNTED 48" MINIMUM TO BASELINE OF LOWEST TACTILE CHARACTER
AND 60" MAXIMUM TO BASELINE OF HIGHEST TACTILE CHARACTER. A CLEAR FLOOR SPACE OF 18" BY 18"
MINIMUM CENTERED ON TACTILE CHARACTERS SHALL BE PROVIDED BEYOND THE ARC OF THE DOOR SWING.
3. RESTROOM DOOR SYMBOL SHALL BE IN CONTRASTING COLOR.
2 RESTROOM ADA SIGNAGE
A-102 SCALE: NTS
MARK
DESCRIPTION
1
EXTERIOR DOOR
EXTERIOR DOOR
EXTERIOR DOOR
DOOR
TYPE
A
EX
EX
SIZE
3'-0" x 7'-0"
EX
EX
THICKNESS MATERIAL
0' - 1 3/4"
EX
EX
HOLLOW METAL
EX
EX
DOOR SCHEDULE
FINISH
FRAME
TYPE
FRAME
MATERIAL
FRAME FINISH
PAINT
EX
EX
1
HOLLOW METAL
EX
EX
EX
EX
PAINT
EX
EX
HEAD
DETAIL
3/A-102
-
-
JAMB
DETAIL
-
-
-
THRESHOLD
2/A-102
-
-
HARDWARE RATING
SET-1
N/A
SET-2
N/A
EX
N/A
DOOR
SCHEDULE
NOTES
1, 2, 3,4
-
DOOR SCHEDULE NOTES:
1. THRESHOLDS SHALL BE NO HIGHER THAN 1/2" AFF, EDGE TO BE BEVELED WITH A SLOPE NO GREATER THAN 1 IN 2.
2. ALONG ACCESSIBLE PATH OF TRAVEL AND AT EGRESS CONDITIONS, DOOR HARDWARE SHALL BE OF THE LEVER OR
PUSH TYPE, MOUNTED 30" TO 44" AFF AND OPERABLE WITH A MAXIMUM EFFORT OF 5 LB. FOR INTERIOR DOORS & 8.5
LB. FOR EXTERIOR DOORS.
3. PROVIDE 18" CLEAR SPACE ON STRIKE/PULL SIDE OF DOORS. PROVIDE 12" CLEAR SPACE ON STRIKE/PUSH SIDE OF
DOORS WITH LATCHES AND/OR CLOSERS.
4. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL, OR SPECIAL KNOWLEDGE OR
EFFORT.
EXTERIOR FINISH SCHEDULE
CATEGORY
DESCRIPTION/FINISH
NEW SPLIT FACE BLOCK & EXISTING SPLIT FACE BLCOK
(2) COATS OF ELASTOMERIC PAINT: COLOR TO BE DETERMINED
DOORS & FRAMING
TOUCH UP EXISTING PAINT AS NEEDED AFTER CONSTRUCTION;
CONTRACTOR TO GET PAINT COLOR FROM CITY
ROOF FASCIA & SOFFIT
TOUCH UP EXISTING PAINT AS NEEDED AFTER CONSTRUCTION;
CONTRACTOR TO GET PAINT COLOR FROM CITY
NOTES:
1) CONTRACTOR TO PAINT INTERIOR OF DOORS. COLOR SW 7015 REPOSE GREY.
2) CONTRACTOR TO PAINT SWATCHES ON EXISTING SPLIT FACE BLOCK WITH TWO COLORS; SW 7015 REPOSE GREY, AND SW 7065 ARGOS.
CITY TO SELECT FINAL COLOR AFTER REVIEW
HARDWARE SCHEDULE
SET #1 1 1/2 PAIR 4 1/2” X 4 1/2” US26D BUTT HINGES
CAL ROYAL OR EQ. KEYED DEADBOLT
CAL ROYAL OR EQ. PUSH/PULL PLATE
LATCH GUARD
RUBBER DOOR SILENCERS
LCN 4030 SERIES CLOSER OR EQUAL
WEATHER STRIP & THRESHOLD
DRIP CAP
SET #2
1 1/2 PAIR 4 1/2” X 4 1/2” US26D BUTT HINGES
CAL ROYAL OR EQ. LEVER LOCK SET (US26D FINISH)
SURFACE MOUNTED CLOSURE
RUBBER DOOR SILENCER
KICK DOWN DOOR HOLDER (US26D FINISH)
WALL MOUNTED DOOR STOP (US26D FINISH)
1, RCI, Model 1300 03P-LTD Electronic Lock
1, RCI, Model 4 Series Commercial Duty Electronic Strike
1, RCI, Model 9321 Electronic Card Reader
SEE ELECTROMAGNETIC LOCK NOTE
NOTE:
ELECTROMAGNETIC LOCKS
Electromagnetic Locks: BHMA A156.23; electrically
powered; with electromagnet attached to frame and
armature plate attached to door; full-exterior or full-interior
type, as required by application indicated.
Manufacturers: Subject to compliance with requirements,
provide products by one of the following:
a. Dortronics Systems, Inc.
b. DynaLock Corp.
c. Schlage Commercial Lock Division; an
Ingersoll-Rand company.
d. Securitron Magnalock Corporation; an ASSA
ABLOY Group company.
AUXILIARY ELECTRIFIED DOOR HARDWARE
Manufacturers: Subject to compliance with requirements,
provide products by one of the following:
1. DynaLock Corp.
2. GE Security, Inc.
3. SARGENT Manufacturing Company; an ASSA
ABLOY Group company.
4. Schlage Commercial Lock Division; an
Ingersoll-Rand company.
5. Securitron Magnalock Corporation; an ASSA
ABLOY Group company.
6. Security Door Controls.
Boxed Power Supplies: Locate power supplies as
indicated or, if not indicated, in electrical equipment room.
Verify location with Architect.
Configuration: Provide least number of power supplies
required to adequately serve doors with electrified door
hardware.
PER SCHEDULE
2"
FINSHED
FLOOR
1 FRAME AND DOOR TYPES
A-102 SCALE:1/4" = 1'-0"
This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...at the Telfair County Recreation Park including +/- 525 LF of 18? RCP ...

State Government of Georgia

Bid Due: 6/11/2026

...Request for Proposals - Ulmer Park Mural Design & Installation by Jennifer Smith ...

City of SpringField

Bid Due: 7/31/2026

...- Noonday Park Addenda: 0 Release Date: 5/15/2026 Due Date: 6/11/2026 Follow Construction ...

Cobb County

Bid Due: 6/11/2026

...Bid Number: 26034-2003 Bid Title: Mt. Tabor Park Connectivity and Additional Parking Category... ...

County of Paulding

Bid Due: 7/08/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.