Fire Alarm System Replacement, Mountain Home AFB

Location: Idaho
Posted: Oct 16, 2025
Due: Dec 1, 2025
Agency: DEPT OF DEFENSE
Type of Government: Federal
Category:
  • J - Maintenance, Repair, and Rebuilding of Equipment
Solicitation No: FA489725R0008
Publication URL: To access bid details, please log in.
Follow
Fire Alarm System Replacement, Mountain Home AFB
Active
Contract Opportunity
Notice ID
FA489725R0008
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Major Command
AIR COMBAT COMMAND
Office
FA4897 366 CONS PKP
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information View Changes
  • Contract Opportunity Type: Solicitation (Updated)
  • Updated Published Date: Oct 16, 2025 03:24 pm MDT
  • Original Published Date: Oct 16, 2025 07:58 am MDT
  • Updated Date Offers Due: Dec 01, 2025 03:00 pm MST
  • Original Date Offers Due: Nov 28, 2025 03:00 pm MST
  • Inactive Policy: Manual
  • Updated Inactive Date: Dec 01, 2026
  • Original Inactive Date: Dec 28, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside: No Set aside used
  • Product Service Code: J063 - MAINT/REPAIR/REBUILD OF EQUIPMENT- ALARM, SIGNAL, AND SECURITY DETECTION SYSTEMS
  • NAICS Code:
    • 236220 - Commercial and Institutional Building Construction
  • Place of Performance:
    Mountain Home AFB , ID 83648
    USA
Description View Changes

Mountain Home AFB, Idaho has a NAF requirement for a design-build service to replace the antiquated fire alarm system at the Sagebrush Inn, building 2320, with a new addressable fire alarm system, as required by the Fire Prevention Engineer. The design-build services shall develop a complete design with supporting specifications, analysis (with hazardous material survey for asbestos and lead-based paints), and proposed construction project schedule; followed by construction services to include demolition (to include abatement of any asbestos and lead-based paint if present); new installation, and commissioning fire alarm systems in accordance with Unified Facility Criteria (UFC); design drawings and specifications; and other design standards and guidance.

Building 2320 has an outdated fire alarm panel and devices which violate the Fire Code requirements. There are no replacement parts available for what is currently installed, which is driving the requirement for a replacement and upgraded system.

It is anticipated that the period of performance will be 407 calendar days from the Notice to Proceed. Design phase being limited to 212 days and construction phase to 180 with the remaining days being used for De-mobilization and Close-out.

Building 2320 will be occupied with Airmen and the everyday mission of those airmen should be minimally disrupted as much as possible. This project will be broken up into 3 phases. Phase 1 will be dedicated to the design of the project and result in the 65% design package being submitted to USG. At the same time the 65% design is delivered Phase 2, which is dedicated to construction, will kick off. Phase 3 will involve tasks finishing up construction, testing, demobilizing, etc.



See attachments below for all relevant documents.



For the proposal, all "if applicable" items shall be priced as if they are all applicable. Any proposals with these items not priced will be deemed unacceptable.



A site visit for any interested parties will be held on October 31st, 2025 at 2:00 PM MST to walk through the facility and have any questions related to the design-build or technical aspects answered. This site visit is not mandatory, and all relevant questions will be recorded and posted to the solicitation after.



Per the evaluation factors,

Questions must be submitted no later than 3:00 PM local (Mountain), Nov 17, 2025.

Proposals must be submitted no later than 3:00 PM local (Mountain), Dec 1, 2025.



Questions shall be directed to both POCs.


Attachments/Links
Contact Information
Contracting Office Address
  • ADMIN ONLY NO REQTN CP 208 828 4658 366 GUNFIGHTER AVE STE 2102
  • MOUNTAIN HOME AFB , ID 83648-5296
  • USA
Primary Point of Contact
Secondary Point of Contact
History

Related Document

Oct 17, 2025[Solicitation (Updated)] Fire Alarm System Replacement, Mountain Home AFB
Oct 30, 2025[Solicitation (Updated)] Fire Alarm System Replacement, Mountain Home AFB
Nov 19, 2025[Solicitation (Updated)] Fire Alarm System Replacement, Mountain Home AFB
Dec 1, 2025[Solicitation (Updated)] Fire Alarm System Replacement, Mountain Home AFB
Dec 4, 2025[Solicitation (Updated)] Fire Alarm System Replacement, Mountain Home AFB
Dec 19, 2025[Solicitation (Updated)] Fire Alarm System Replacement, Mountain Home AFB
Jan 14, 2026[Solicitation (Updated)] Fire Alarm System Replacement, Mountain Home AFB
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.