Y1DA--630A4-26-401 MRI AHU Modification
| Location: |
Federal |
| Posted: |
Aug 26, 2026 |
| Due: |
Aug 28, 2026 |
| Agency: |
VETERANS AFFAIRS, DEPARTMENT OF |
| Type of Government: |
Federal |
| Category: |
- Y - Construction of Structures and Facilities
|
| Solicitation No: |
36C24226R0060 |
| Publication URL: |
To access bid details, please log in. |
Y1DA--630A4-26-401 MRI AHU Modification
Active
Contract Opportunity
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
242-NETWORK CONTRACT OFFICE 02 (36C242)
Looking for contract opportunity help?
General Information View Changes
-
Contract Opportunity Type: Solicitation (Updated)
-
Updated Published Date: Aug 26, 2026 09:13 am EDT
-
Original Published Date: Apr 27, 2026 11:58 am EDT
-
Updated Date Offers Due: Aug 28, 2026 12:00 pm EDT
-
Original Date Offers Due: May 26, 2026 12:00 pm EDT
-
Inactive Policy: Manual
-
Updated Inactive Date: Sep 27, 2026
-
Original Inactive Date:
Sep 02, 2026
-
Initiative:
Classification
-
Original Set Aside:
-
-
Product Service Code: Y1DA - CONSTRUCTION OF HOSPITALS AND INFIRMARIES
-
NAICS Code:
-
236220 - Commercial and Institutional Building Construction
-
Place of Performance:
Description View Changes
36C24226R0060
Amendment 5
630A4-26-401 MRI AHU Modification
8. Question -Hallway Fan Coil Units-The contract documents indicate (6) 18,000 BTU/h chilled water surface-mounted fan coil units in the hallway. We have concerns with this configuration: the surface-mounted units would protrude into the corridor, presenting both an aesthetic issue and a potential head-strike hazard for pedestrians. We propose substituting ceiling-mounted fan coil units in lieu of the surface-mounted units. Please advise which of the following options is acceptable:
VA Response: Option A would be acceptable if there is no additional cost to the VA. Six ceiling mounted units would provide both the desired level of equipment redundancy and distributed air flow equivalent to the contract design wall mounted units. An 18,000 btu wall mounted evaporator fan unit requires a minimum of 6 inches of clearance below the ceiling for proper air flow. As the evaporator fan coil unit is approximately 12-14 inches high, in an 8 foot high corridor (96 inches clear), there would be a minimum of 76 inches clearance under the evaporator fan unit, or 6 foot 3 inches. If the corridor is higher than 8 feet then the clearance would increase.
Option A: Provide (6) ceiling-mounted fan coil units at 18,000 BTU/h each; note that due to ceiling constraints, the units cannot be equally spaced along the corridor.
Option B: Provide (3) ceiling-mounted fan coil units of higher capacity, sized to provide equivalent total cooling capacity, spaced evenly along the corridor.
Attachments/Links
Contact Information
Contracting Office Address
-
113 HOLLAND AVE
-
ALBANY , NY 12208
-
USA
Secondary Point of Contact
History
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
See also
Follow USACE SPK Construction - Natomas PP5, Sacramento, CA Active Contract Opportunity Notice
DEPT OF DEFENSE
Bid Due: 9/01/2026
Follow CIRCUIT CARD ASSEMB Active Contract Opportunity Notice ID N0010426QUC02 Related Notice Department/Ind.
DEPT OF DEFENSE
Bid Due: 9/10/2026
Follow RING,RETAINING Active Contract Opportunity Notice ID N0010426QFG17 Related Notice Department/Ind. Agency DEPT
DEPT OF DEFENSE
Bid Due: 9/08/2026
Follow Calcasieu River and Pass, LA, Maintenance Dredging FY26, Mile 5.0 to Mile
DEPT OF DEFENSE
Bid Due: 9/16/2026
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.